General · Topic G0 · 2 exam questions
Electrical and RF Safety
Staying safe around RF energy, household wiring, lightning, towers and generators, including FCC RF exposure rules.
Ham radio involves strong RF fields, household power, tall towers and lightning. This topic covers how to keep yourself and others safe: the FCC rules on RF exposure, plus electrical wiring, grounding and tower safety. Safety questions show up on every exam, and these habits protect you for life.
G0A · RF exposure rules
How RF affects the body: RF energy heats body tissue, much like a microwave oven. Radio waves are non-ionizing, so they do not cause radiation poisoning.
What determines exposure:
- Power density: how much RF power hits each area
- Frequency: the body absorbs some frequencies more than others
- Duty cycle: how much of the time the transmitter is on
All three matter.
Who is covered: FCC RF exposure rules apply to all stations with a time-averaged transmission of more than 1 milliwatt. Ham stations are not exempt.
Time averaging means looking at the total RF exposure averaged over a certain period, not one instant. Because of this, a lower duty cycle permits higher power. A low duty cycle does not, however, exempt you from evaluation.
Checking your station (FCC rule 97.13): You must do a routine RF exposure evaluation and keep people out of any high exposure areas. You can evaluate by:
- Calculation using FCC OET Bulletin 65
- Computer modeling
- Measurement with calibrated equipment
Any of these is acceptable. To measure accurately, use a calibrated field strength meter with a calibrated antenna. An SWR meter or regular receiver will not do.
Exemptions: Some stations are exempt from a full evaluation, for example low-power ones. If your station does not meet the exemption criteria, you must perform an evaluation following OET Bulletin 65.
If you are over the limits: you must take action to prevent human exposure. Options include lowering power, raising or moving the antenna, or keeping people out of the area. There is no form to file, and neighbors cannot give permission to exceed limits.
Practical cases:
- Directional antenna aimed at a neighbor: make sure the antenna cannot be pointed toward them when they are present.
- Indoor antenna: make sure the MPE (Maximum Permissible Exposure) limits are not exceeded in rooms where people spend time.
You do not need to post Part 97 in your shack or notify neighbors.
G0B · Electrical, lightning and tower safety
Fuses and breakers go on the hot wires only. In a four-wire 240 VAC circuit, that means the two hot wires, never the neutral or ground.
Wire size and breaker size (National Electrical Code, copper wire). In the AWG system, a smaller number means thicker wire.
| Wire size | Maximum breaker or fuse |
|---|---|
| AWG 14 | 15 amps |
| AWG 12 | 20 amps |
So a 20-amp circuit needs at least AWG 12, and AWG 14 wire gets a 15-amp breaker. A breaker that is too big lets thin wire overheat.
The National Electrical Code (NEC) covers the electrical safety of your station. It does not cover bandwidth, modulation or RF exposure.
GFCI (ground fault circuit interrupter): cuts the power when current flows from a hot wire directly to ground, such as through a person. Normal hot-to-neutral current does not trip it.
Power supply interlock: removes dangerous voltages when the cabinet is opened.
Lightning protection:
- The lightning ground system goes outside the building.
- Lightning arrestors go where the feed lines enter the building.
- All ground rods must be bonded together with all other grounds, so they stay at the same voltage.
Tower safety:
- Check that your safety harness is rated for your weight and is within its service life.
- Before climbing a tower with powered equipment, make sure all circuits are locked out and tagged, so no one can turn them on while you climb.
Generators: run them in a well-ventilated area because they make deadly carbon monoxide. Store fuel away from the generator.
Solder: lead can get into your food if you do not wash your hands after soldering.
Quick review
- RF heats body tissue; it does not cause radiation poisoning.
- Exposure depends on power density, frequency and duty cycle.
- Rules cover all stations averaging more than 1 milliwatt.
- Evaluate by calculation (OET Bulletin 65), modeling or measurement, then keep people out of hot spots.
- Lower duty cycle permits more power.
- Fuse only the hot wires. AWG 14 = 15 A; AWG 12 = 20 A.
- GFCI trips on current from hot to ground.
- Lightning ground outside; arrestors where feed lines enter; bond all grounds together.
- Lock out and tag tower power before climbing, and check your harness.
- Run generators in fresh air; wash your hands after handling lead solder.
Ready to check yourself?
Drill all 25 questions from G0. You'll see the answer and explanation after each one.
Every question in G0
Tap a question to see the answer and why.
G0A · 12 questions
– RF safety principles, rules, and guidelines; routine station evaluation
G0A01What is one way that RF energy can affect human body tissue?
- AIt heats body tissue (correct answer)
- BIt causes radiation poisoning
- CIt causes the blood count to reach a dangerously low level
- DIt cools body tissue
RF energy, especially at higher power and close range, can heat body tissue, the same way a microwave oven heats food. It does not cause radiation poisoning, because radio waves are non-ionizing; they do not have enough energy to break molecules apart. Memory tip: RF warms, it does not irradiate.
G0A02Which of the following is used to determine RF exposure from a transmitted signal?
- AIts duty cycle
- BIts frequency
- CIts power density
- DAll these choices are correct (correct answer)
RF exposure depends on several things. Power density is how much RF power hits each area, the frequency matters because the body absorbs some frequencies more, and duty cycle sets how often the transmitter is actually on. All three are used to work out exposure. Memory tip: power, frequency and on-time all count.
G0A03How can you determine that your station complies with FCC RF exposure regulations?
- ABy calculation based on FCC OET Bulletin 65
- BBy calculation based on computer modeling
- CBy measurement of field strength using calibrated equipment
- DAll these choices are correct (correct answer)
FCC rule 97.13 lets you check RF exposure in several ways. You can calculate it using FCC OET Bulletin 65, use computer modeling, or measure the field with calibrated equipment. Any of these works. Memory tip: calculate, model or measure, all acceptable.
FCC rule §97.13G0A04What does “time averaging” mean when evaluating RF radiation exposure?
- AThe average amount of power developed by the transmitter over a specific 24-hour period
- BThe average time it takes RF radiation to have any long-term effect on the body
- CThe total time of the exposure
- DThe total RF exposure averaged over a certain period (correct answer)
Time averaging means looking at the total RF exposure over a set period of time, not just one instant. Since you do not transmit nonstop, the average exposure is lower than the peak. The FCC uses about 6 minutes for controlled settings and 30 minutes for the public. Memory tip: average the exposure over time.
G0A05What must you do if an evaluation of your station shows that the RF energy radiated by your station exceeds permissible limits for possible human absorption?
- ATake action to prevent human exposure to the excessive RF fields (correct answer)
- BFile an Environmental Impact Statement (EIS-97) with the FCC
- CSecure written permission from your neighbors to operate above the controlled MPE limits
- DAll these choices are correct
If your station puts out RF fields above the safe limits where people could be, you must take action so no one is exposed. You might lower power, move the antenna or keep people out of the area. There is no form to file and neighbors cannot sign it away. Memory tip: too much RF means protect the people.
FCC rule §97.13G0A06What must you do if your station fails to meet the FCC RF exposure exemption criteria?
- APerform an RF exposure evaluation in accordance with FCC OET Bulletin 65 (correct answer)
- BContact the FCC for permission to transmit
- CPerform an RF exposure evaluation in accordance with World Meteorological Organization guidelines
- DUse an FCC-approved band-pass filter
Some stations are exempt from a full RF evaluation because they are low power or far away. If your station does not meet the exemption rules, you must do an RF exposure evaluation using the methods in FCC OET Bulletin 65. You do not need FCC permission to transmit. Memory tip: not exempt means evaluate with OET 65.
FCC rule §97.13G0A07What is the effect of modulation duty cycle on RF exposure?
- AA lower duty cycle permits greater power levels to be transmitted (correct answer)
- BA higher duty cycle permits greater power levels to be transmitted
- CLow duty cycle transmitters are exempt from RF exposure evaluation requirements
- DHigh duty cycle transmitters are exempt from RF exposure requirements
Duty cycle is the share of time a transmitter is on. If it is only on part of the time, the average RF exposure is lower, so you can safely use more peak power. A lower duty cycle permits more power, but it does not make you exempt from evaluation. Memory tip: less on-time, more power allowed.
G0A08Which of the following steps must an amateur operator take to ensure compliance with RF safety regulations?
- APost a copy of FCC Part 97.13 in the station
- BNotify neighbors within a 100-foot radius of the antenna of the existence of the station and power levels
- CPerform a routine RF exposure evaluation and prevent access to any identified high exposure areas (correct answer)
- DAll these choices are correct
FCC rule 97.13 requires you to evaluate your station's RF exposure and keep people out of any areas that are over the limits. You do not have to post the rule or notify neighbors. Memory tip: evaluate it, then fence off the hot spots.
FCC rule §97.13G0A09What type of instrument can be used to accurately measure an RF field strength?
- AA receiver with digital signal processing (DSP) noise reduction
- BA calibrated field strength meter with a calibrated antenna (correct answer)
- CAn SWR meter with a peak-reading function
- DAn oscilloscope with a high-stability crystal marker generator
To measure RF field strength accurately, you need a calibrated field strength meter with a calibrated antenna. An SWR meter only shows how well your feed line is matched, and a regular receiver is not calibrated for field strength. Memory tip: accurate measuring needs calibrated gear.
G0A10What should be done if evaluation shows that a neighbor might experience more than the allowable limit of RF exposure from the main lobe of a directional antenna?
- AChange to a non-polarized antenna with higher gain
- BUse an antenna with a higher front-to-back ratio
- CTake precautions to ensure that the antenna cannot be pointed in their direction when they are present (correct answer)
- DAll these choices are correct
A directional antenna's main lobe is its strongest direction. If it could expose a neighbor to too much RF, make sure the antenna cannot be pointed their way when they are present, for example by limiting the rotator. Switching to a higher-gain antenna would make it worse. Memory tip: do not aim the main lobe at people.
G0A11What precaution should be taken if you install an indoor transmitting antenna?
- ALocate the antenna close to your operating position to minimize feed-line radiation
- BPosition the antenna along the edge of a wall to reduce parasitic radiation
- CMake sure that MPE limits are not exceeded in occupied areas (correct answer)
- DMake sure the antenna is properly shielded
An indoor antenna is close to people, so RF exposure is a real concern. You need to make sure the Maximum Permissible Exposure (MPE) limits are not exceeded anywhere people spend time. Putting it close to your operating chair would make exposure worse. Memory tip: indoor antenna, check MPE where people are.
G0A12What stations are subject to the FCC rules on RF exposure?
- AAll commercial stations; amateur radio stations are exempt
- BOnly stations with antennas lower than one wavelength above the ground
- COnly stations transmitting more than 500 watts PEP
- DAll stations with a time-averaged transmission of more than one milliwatt (correct answer)
FCC RF exposure rules cover all stations, ham ones included, that transmit with a time-averaged power over 1 milliwatt. Hams are not exempt, and there is no special 500-watt cutoff. In practice, almost every ham station is covered, though many qualify for exemptions from a full evaluation. Memory tip: more than 1 mW, the rules apply.
G0B · 13 questions
– Station safety: electrical shock, grounding, fusing, interlocks, and wiring; antenna and tower safety
G0B01Which wire or wires in a four-conductor 240 VAC circuit should be attached to fuses or circuit breakers?
- AOnly the hot wires (correct answer)
- BOnly the neutral wire
- COnly the ground wire
- DAll wires
In a 240 VAC circuit with two hot wires, a neutral and a ground, the fuses or breakers go only on the hot wires. The neutral and ground must never be broken by a fuse, because that could leave equipment energized without a safe return path. Memory tip: fuse the hots, never the neutral or ground.
G0B02According to the National Electrical Code, what is the minimum wire size that may be used safely for wiring with a 20-ampere circuit breaker?
- AAWG number 20
- BAWG number 16
- CAWG number 12 (correct answer)
- DAWG number 8
Under the National Electrical Code, a 20-amp circuit needs at least AWG 12 copper wire. In the AWG system, smaller numbers mean thicker wire. AWG 14 is only good for 15 amps, and AWG 16 or 20 is far too thin. Memory tip: 20 amps needs 12 gauge.
G0B03Which size of fuse or circuit breaker would be appropriate to use with a circuit that uses AWG number 14 wiring?
- A30 amperes
- B25 amperes
- C20 amperes
- D15 amperes (correct answer)
AWG 14 copper house wire is rated for 15 amps, so a 15-amp fuse or breaker protects it. A bigger breaker would let the thin wire overheat before tripping, which could start a fire. Memory tip: 14 gauge pairs with 15 amps, and 12 gauge with 20 amps.
G0B04Where should the station’s lightning protection ground system be located?
- AAs close to the station equipment as possible
- BOutside the building (correct answer)
- CNext to the closest power pole
- DParallel to the water supply line
Lightning protection grounds belong outside the building, where the surge can be sent into the earth before it gets inside. Putting the ground next to your equipment would bring lightning energy indoors. Memory tip: stop lightning outside.
G0B05Which of the following conditions will cause a ground fault circuit interrupter (GFCI) to disconnect AC power?
- ACurrent flowing from one or more of the hot wires to the neutral wire
- BCurrent flowing from one or more of the hot wires directly to ground (correct answer)
- COvervoltage on the hot wires
- DAll these choices are correct
A GFCI compares the current going out on the hot wire with the current returning on the neutral. If some current is leaking to ground, perhaps through a person, the two do not match and the GFCI shuts off power fast. Normal hot-to-neutral current is how a device runs. Memory tip: GFCI trips on hot-to-ground leaks.
G0B06Which of the following is covered by the National Electrical Code?
- AAcceptable bandwidth limits
- BAcceptable modulation limits
- CElectrical safety of the station (correct answer)
- DRF exposure limits of the human body
The National Electrical Code (NEC) sets rules for safe electrical wiring, including the wiring and grounding in your ham station. It does not cover bandwidth, modulation or RF exposure, which are FCC topics. Memory tip: NEC = electrical safety.
G0B07Which of these choices should be observed when climbing a tower using a safety harness?
- AAlways hold on to the tower with one hand
- BConfirm that the harness is rated for the weight of the climber and that it is within its allowable service life (correct answer)
- CEnsure that all heavy tools are securely fastened to the harness
- DAll these choices are correct
Before climbing, check that your safety harness is rated for your weight and has not passed its service life, since old webbing gets weak. Holding on with one hand is not the rule, and heavy tools should be raised with a rope, not hung on you. Memory tip: check the harness rating and age.
G0B08What should be done before climbing a tower that supports electrically powered devices?
- ANotify the electric company that a person will be working on the tower
- BMake sure all circuits that supply power to the tower are locked out and tagged (correct answer)
- CUnground the base of the tower
- DAll these choices are correct
Before climbing a tower that holds powered equipment like lights or amplifiers, shut off every circuit feeding it and use lockout and tagout. A lock and tag keep anyone from turning the power back on while you are up there. Never unground the tower. Memory tip: lock it out, tag it, then climb.
G0B09Which of the following is true of an emergency generator installation?
- AThe generator should be operated in a well-ventilated area (correct answer)
- BThe generator must be insulated from ground
- CFuel should be stored near the generator for rapid refueling in case of an emergency
- DAll these choices are correct
Generators make carbon monoxide, a gas you cannot see or smell that can kill. Always run them outdoors in an area with plenty of fresh air, never in a garage or house. Fuel should be kept away from the generator. Memory tip: generators go outside where air flows.
G0B10Which of the following is a danger from lead-tin solder?
- ALead can contaminate food if hands are not washed carefully after handling the solder (correct answer)
- BHigh voltages can cause lead-tin solder to disintegrate suddenly
- CTin in the solder can “cold flow,” causing shorts in the circuit
- DRF energy can convert the lead into a poisonous gas
Lead in solder can stick to your hands. If you eat without washing up, the lead can get into your food and your body, which is harmful. RF cannot turn lead into gas. Memory tip: wash your hands after soldering.
G0B11Which of the following is required for lightning protection ground rods?
- AThey must be bonded to all buried water and gas lines
- BBends in ground wires must be made as close as possible to a right angle
- CLightning grounds must be connected to all ungrounded wiring
- DThey must be bonded together with all other grounds (correct answer)
All ground rods and grounding systems in a home, including the station and electrical service grounds, must be bonded together, meaning connected with heavy wire. This keeps them at the same voltage so a lightning surge does not jump between them through your equipment. Memory tip: bond all grounds together.
G0B12What is the purpose of a power supply interlock?
- ATo prevent unauthorized changes to the circuit that would void the manufacturer’s warranty
- BTo shut down the unit if it becomes too hot
- CTo ensure that dangerous voltages are removed if the cabinet is opened (correct answer)
- DTo shut off the power supply if too much voltage is produced
A power supply interlock is a safety switch that cuts off dangerous high voltage when you open the cabinet. Opening the case breaks the circuit, so you are less likely to touch live parts. Memory tip: open the case, the power goes off.
G0B13Where should lightning arrestors be located?
- AWhere the feed lines enter the building (correct answer)
- BOn the antenna, opposite the feed point
- CIn series with each ground lead
- DAt the closest power pole ground electrode
Lightning arrestors go where the feed lines enter the building. That way a surge on the coax is sent to the outside ground before it gets indoors to your equipment. Memory tip: catch the lightning at the door.